LCR Tester HIOKI 3535

HIOKI LCR Tester High-speed LCR meter with sampling rate up to 120MHz

  • Wide frequency band from 100kHz to 120MHz
  • High-speed LCR testing (6ms/sampling)
  • Removable preamplifier optional
  • Load compensation function" to provide compensation for comparison standard components

The LCR tester 3535 amplifier unit (9700-10) is a factory line option, and is a fixed option when ordering. (The LCR tester 3535 input probe/test fixture is not supplied with the unit. Different probe/test fixture options are available for different models depending on the measurement purpose

分享

相关产品

 
 

Basic parameters:

  • Measurement parameters |Z|, |Y|, Q, Rp, Rs(ESR), G, X, B, θ, Ls, Lp, Cs, Cp, D(tanδ)
  • Preamplifier
  • Determined measurement range
  • Preamplifier 9700-019700-029700-03
  • Z and R:100mΩ~1kΩ 500Ω~10kΩ 5kΩ~100kΩ
  • C:1.33pF~15.9μF 0.133pF~3.18nF 0.1pF~318pF
  • L:1nH~1.59mH 663nH~15.9mH 6.63μH~159mH
  • Θ:-180.00°~180.00°
  • Measuring frequency range 100kHz~120MHz
  • Resolution setting 4 bits (set by control board before use)
  • 100.0kHz~1.000MHz 100Hz amplitude
  • 1.000MHz~10.00MHz 1kHz amplitude
  • 10.00MHz~100.0MHz 10kHz amplitude
  • 100.0MHz~120.0MHz 100kHz amplitude

 

When using GP-IB or RS-232C interface, the resolution is 1Hz. accuracy ± 0.005% max. relative to the set value measurement level open-circuit interface voltage (V) and constant voltage (CV) mode 5mV ~ 1V, max. 20mA (below 10.000MHz) 5mV ~ 500mV, max. 10mA (above 10.01MHz) resolution 1mV amplitude Accuracy ± (5% + 5mV) × (2 + log f) (f is the number of MHz) constant current (CC) mode 200μA ~ 20mA, maximum 1V (below 10.00MHz) 200μA ~ 10mA, maximum 0.5V (above 10.01MHz) resolution 10A amplitude accuracy ± (10% + 50μA) × (2 + log f) (f is the number of MHz) Basic accuracy Z: ± 0.5% rdg. θ: ± 0.3° Output impedance 50Ω ± 10Ω (at 100kHz) Monitoring voltage 0.000V to 1.000V Current 0.000mA to 20.0mA Limit voltage (set to CC) 0.005V to 1.000V Current (set to V or CV) 0.20mA to 20.00mA Average off, 2. 4, 8, 16, 32, 64 trigger built-in trigger, external trigger trigger delay 0.01s ~ 9.99s; 0.01s resolution comparison can be obtained from two sets of measurement parameters: percentage, △%, or absolute value setting (△% that shows the deviation of the measured value from the standard value) control panel storage and recall of up to 30 groups of screen display measured values and the results of the comparator judgment display line number can be set to 3, the 4, or 5; depending on the parameters may vary print copy of measured values or screen display points (requires 9442, 9593-01 and 9446) Interface GP-IB, RS-232C, EXT.I/O (all standards) Operating environment 10 to 40°C, maximum 80% rh, no condensation Storage environment -10 to 55°C, maximum 80% rh, no condensation Power supply Power supply AC 100V ~ 240V, 50/60Hz, about 50VA Volume and weight about 360 width × 130 height × 360 thickness (mm); 8.3kg